Numatics Catalogo Entrega Inmediata.pdf


Vista previa del archivo PDF numatics-catalogo-entrega-inmediata.pdf


Página 1...16 17 18192074

Vista previa de texto


2002 Series

Valves

02 Series and R2 Series

02 Series
0ORTED ANDPOSITION  WAY 3POOL3LEEVE
#V

(A)
(B)(A)
(B)
14
2 4 solenoid air
12single

R2 Series

pilot

2 position 4-way

0ORTED ANDPOSITION  WAYANDDUAL WAY
0ACKED3POOL

(B) 3(B)(A)
15
2 4
12(EB)(P)(EA)

(A)
14

s

Solenoid air pilot actuated

s

,OWWATTAGEPLUG IN WATTFOR$#APPLICATION

s

%LIMINATIONOFINTERNALWIRING

s

0USHERPISTONnHIGHSPOOLSHIFTINGFORCE

s

#OMPACTMODULAR&IELDBUSELECTRONICS

s

)NTERCHANGEABLE0USH )NFITTINGSTOACCOMMODATE

(B)(A)
(B)
2 4
12double solenoid

(B)(A)
31
2 54
(EB)(P)(EA)

(A)
14

(B)(A)

(A)

(B)(A)
315
2 4
(EB)(P)(EA)

(A)
14

double solenoid 3 position
315
4-way
closed center
(EB)(P)(EA)
(B)(A)

(B)

(A)

24
double
solenoid
air pilot
14
12
3 position 4-way closed center
(B)(A)
2341 5
(EB)(P)(EA)

(B)
12

(A)
14

315
(EB)(P)(EA)

R2 Series(EB)(P)(EA)
Only
double solenoid
air pilot dual 3-way
“12(B)” & “14(A)” NC

(B)
12

(B)
2

3
(EB)

(A)
4

1
(P)

(A)
14

5
(EA)

02 Series - Operating Data

02 Series - Technical Data
Cv

(B)

12
2solenoid
4
double
air14pilot
2 position 4-way

315

VARIOUSTUBESIZES

Valve Data

(A)

air pilot
14
3 position 4-way open center

(B)
12

double solenoid air pilot
2 position 4-way

(B)
12

double solenoid 3 position
315
4-way
open center
(EB)(P)(EA)

#V WAY $UAL WAY

English

Metric

All solenoids are
continuous duty rated

24 VDC

0.20

0.20

3#&- 03)'
UPSTREAMPRESSURETO
ATMOSPHERE

.)M BAR
UPSTREAMTOBARDOWNSTREAM

(G6ACUUMTO
03)'

6ACUUMTOBAR

Response time in sec.

Energize

De-energize

0ILOT0RESSURE2ANGE

TO03)'

2.5 to 7 bar

 0OSITION 3INGLE 3PRING2ETURN

0.014

0.020

4EMPERATURE2ANGE!MBIENT

ƒ&TO ƒ&

ƒ#TO ƒ#

 0OSITION $OUBLE $ETENTED

0.010

N/A

 0OSITION 3PRING#ENTERED

0.009

0.057

&LOW#APACITY
/PERATING0RESSURE2ANGE

R2 Series - Technical Data
Valve Data

English

Cv
&LOW#APACITY
/PERATING0RESSURE2ANGEWAY
$UAL7AY
0ILOT0RESSURE2ANGE
4EMPERATURE2ANGE!MBIENT

14

single solenoid air pilot
2 position 4-way

0OWER7ATTS

0.50

(OLDING#URRENT!MPS

0.02

R2 Series - Operating Data
Metric

0.25

0.25

3#&- 03)'
UPSTREAMPRESSURETO
ATMOSPHERE

.)M BAR
UPSTREAM
TOBARDOWNSTREAM

28” Hg.
6ACUUMTO
03)'

6ACUUMTO
bar

TO03)'

0 to 7 bar

35 to 100
03)'

2.5 to 7 bar

ƒ&TO
ƒ&

ƒ#TO ƒ#

All solenoids are
continuous duty rated

24 VDC

0OWER7ATTS

0.50

(OLDING#URRENT!MPS

0.02

Response time in sec.

Energize

De-energize

 0OSITION 3INGLE 3PRING2ETURN

0.017

0.013

 0OSITION $OUBLE $ETENTED

0.010

N/A

 0OSITION 3PRING#ENTERED

0.009

0.022

$UAL WAY

0.018

0.010

For detailed dimensional information and technical specifications, please visit www.numatics.com. Information subject to change without notice.