The output voltage is not correct

- Using a digital or analog voltmeter
- Use a RMS reading voltmeter.
- The input DC voltage is too low or too high.
- Adjust the voltage to the requires level.

Unable to manage the charge

- The charge is too large or potency is too large.
- Use a lower charge.
- The cabling is wrong or the connection is not safe.
- Use adequate cables.
- The startup is more than 2 times the average.
- Try another application.

Unable to restore the
inverter when this
goes into protection mode

- Check the temperature of the inverter, if this
is more than 65 º C Let rest for the invester
approximately 15 minutes.
- Check that your battery is in good condition.
- If the problem persists please contact the
telephone customer service.

SPECIFICATIONS
Cable
Gauge
INV-300

13 AWG

INV-400

11 AWG

INV-600

9.5 AWG

INV-1000

7 AWG

INV-1500

5 AWG